Version 7.12.11
Problem(s) fixed:
- Fixed a problem with 4H in which a spanned array is broken by copying the configuration from the drives
- Fixed a problem on the 7k tape support with SCSI pass-through status in Windows 2000/2003
Enhancement: N/A
Limitations: N/A
Dependencies: N/A
Version 7.12.07
Problem(s) fixed:
- Fixed a problem with error recovery for media errors on RAID levels 1 and 5
Enhancement: N/A
Limitations: N/A
Dependencies: N/A
Version 7.12.04
Problem(s) fixed:
- Fixed a problem with defunct drive not able to be replaced. If a drive is DDD and is not part of an array, the FW now allows the user to change the drive
state from DDD to DHS using ipssend. - Fixed a problem with failure to import configuration on 7k when replacing both the controller and a bad drive at the same time.
- Removed 48 hour time limit for rebuild operations. 2TB RAID 1E0 arrays can take over 48 hours to rebuild. Rebuild timeout is now 10 minutes per stripe.
Enhancement: N/A
Limitations: N/A
Dependencies: N/A
Version 7.10
Problem(s) fixed:
- Fixed a problem with the ServeRAID-5i firmware concerning dead battery recognition.
Enhancement: N/A
Limitations: N/A
Dependencies: N/A
Version 6.11
Problem(s) fixed:
- Fixed a problem with tape drive firmware updates.
Enhancement: N/A
Limitations: N/A
Dependencies: N/A
Version 6.00
Problem(s) fixed: N/A
Enhancement:
- Initial release supporting IBM ServeRAID-6i and ServeRAID-6M Ultra320 SCSI controller.
Limitations: N/A
Dependencies: N/A
To view PDF files you must have the latest version of Adobe Acrobat installed on your system.
Get Adobe® Reader®