Overview - IBM 1000VA, 1500VA LCD Tower UPS (5396)



At a glance

Power Supply (UPS) offerings provide power protection with increased efficiency and simplified power management to safeguard high-availability IBM System x server environments.

IBM System x server environments.

  • 1000VA (750 W), and 1500VA (1000 W) tower offerings
  • 95+% energy efficiency across line at 100% load
  • Nine-language graphical Liquid Crystal Display (LCD) which provides intuitive management and monitoring capabilities
  • Hot-swappable batteries for maximum uptime, availability, and ease of maintenance
  • ABM three-stage charging technology significantly extends battery service life and optimizes recharge time
  • Standard intelligent Power Manager Supervisory software to monitor, manage, and to gradually shut down the connected load in the event of a power failure
  • Optional Network Management Card (46M4110) for enhanced UPS monitoring and control
  • Optional Environmental Monitoring Probe (46M4113) for thermal management requirements
  • Integration with IBM Systems Director Active Energy Manager (AEM) for single pane of glass power and thermal trending analysis and management

Overview

In today's high availability server environments, unplanned power outages or line quality irregularities can have a considerable financial impact on small, medium, and large enterprise businesses. Selecting the right uninterruptible power supply (UPS) can efficiently, reliably, and affordably help protect against these potentially costly incidents.

The new power-dense IBM 1000VA and 1500VA LCD Tower UPS offerings provide maximum protection, increased efficiency, and simplified power management to safeguard small offices or System x distributed tower server environments.

IBM 5396 UPS tower offerings come in space-efficient 1.0kVA and 1.5kVA tower designs. These models are equipped to meet the requirements of
your highest availability systems with geography-specific high-voltage and low-voltage solutions available.

  • 1000 VA/750 W Tower
    • 53961AX (120V) with eight NEMA 5-15R
    • 53961JX (100V) with eight NEMA 5-15R
    • 53961KX (230V) with eight IEC 320 C13 receptacles
  • 1500 VA/1000 W Tower
    • 53962AX (120V) with eight NEMA 5-15R
    • 53962JX (100V) with eight NEMA 5-20R
    • 53962KX (230V) with eight IEC 320 C13 receptacles

These units are designed to operate at a greater than 95% efficiency rating at full load and can increase uptime, with next-generation power
protection, while helping reduce operating costs.

These new offerings also provide intuitive power management and monitoring capabilities. The intelligent three-button, dual-color backlight graphical Liquid Crystal Display (LCD) features a bright, easy-to-navigate panel that provides configurability and displays important status information in nine languages - English, French, German, Spanish, Russian, Korean, Japanese, Simplified Chinese, and Traditional Chinese. Runtime, load troubleshooting, and other vital information are also ex-hibited. Intelligent power manager supervisory software is also standard to monitor, manage, and to gradually shut down the connected server loads in the event of an extended power interruption.

They also come equipped with a communication bay for installation of an optional Network Management Card (46M4110). The Network Management Card
provides convenient over-the-network UPS remote monitoring and management through a standard Web browser. An optional Environmental Monitoring Probe (46M4113) is also available for thermal (temperature and humidity) management requirements.

IBM Systems Director Active Energy Manager (AEM) provides an array of new features that allow power and thermal trending analysis for improved power management. By plugging systems into an IBM UPS, AEM is able to collect power information for each device, presenting a more complete view of energy usage within the data center. With access to accurate, detailed information on power usage right at their fingertips, IT and facility managers are now able to manage their data center for optimal energy efficiency, migrating workloads to alleviate hot spots or transferring work from underutilized systems to conserve energy.

The new IBM 5396 UPSs also feature ABM(R) technology, which incorporates sophisticated sensing circuitry and an innovative three-stage charging
technique to significantly extend battery service life and optimize recharge time. ABM also provides up to a 60-day notification when a hot-swappable battery is approaching the end of its useful life. Hot-swappable batteries enable maximum uptime, availability, and ease of maintenance.

All 5396 units come equipped with intelligent load segments. These individual receptacle groups can be programmed and controlled allowing mission-critical devices to be prioritized during shutdown to preserve battery runtime.

Key prerequisites

The following customer-supplied wall outlets are required:

  • UPS 1000VA and 1500VA LCD Tower UPS - 100 V to 230 V, 10 A to 6.5 A circuit (single-phase)

Warranty

  • Three years limited warranty
  • Optional features - One year limited warranty

Packaging

IBM 1000VA LCD Tower UPS one box

IBM 1500VA LCD Tower UPS one box

Base UPS with X-SNMP / Web Adapter Card with Serial Functionality

Accessory kit, includes:

  • Serial Cable (3.7 m, 12 ft.)
  • USB Cable
  • REPO Connector

Documentation Kit, includes:

  • Important Notices Manual
  • Warranty Flyer
  • Documentation CD
  • Software CD

The 1000VA and 1500VA LCD Tower UPS is shipped as a single package. Other items are in zipped bags.

Physical specifications

IBM 1000VA LCD Tower UPS

Dimensions

  • Approximate height: 246 mm (9.7 inch)
  • Approximate width: 160 mm (6.3 inch)
  • Approximate depth: 436 mm (17.2 inch)
  • Approximate weight: 14.3 kg (31.5 lb)

Shipping Dimensions

  • Approximate height: 270 mm (10.6 inch)
  • Approximate width: 600 mm (23.6 inch)
  • Approximate depth: 800 mm (31.5 inch)
  • Approximate weight: 27.5 kg (60.7 lb) - 1AX, 28.6 kg (63.0 lb) - 1KX

IBM 1500VA LCD Tower UPS

Dimensions

  • Approximate height: 246 mm (9.7 inch)
  • Approximate width: 160 mm (6.3 inch)
  • Approximate depth: 436 mm (17.2 inch)
  • Approximate weight 19.0 kg (41.9 lb)

Shipping Dimensions

  • Approximate height: 270 mm (10.6 inch)
  • Approximate width: 600 mm (23.6 inch)
  • Approximate depth: 1000 mm (39.4 inch)
  • Approximate weight: 40.3 kg (88.7 lb) - 2AX, 40.5 kg (89.3 lb) - 2KX

Electrical Specification

  • UPS 1,000 VA / 750 W Tower - (single-phase)
    • 53961AX 1000 VA, 120 V AC, 60 Hz, 8.8 A
  • Output through 8 NEMA 5-15R receptacles
    • 53961JX 1000 VA, 100 V AC, 60 Hz, 10.5 A
  • Output through 8 NEMA 5-15R receptacles
  • UPS 1,000 VA / 750 W Tower - (single phase)
    • 53961KX 1,000 VA, 220-240 V AC, 50 Hz, 4.6 A
  • Output through 8 IEC 320 C13 receptacles
  • UPS 1,500 VA / 1000 W Tower - (single phase)
    • 53962AX 1440 VA, 120 V AC, 60 Hz, 12.6 A
  • Output through 8 NEMA 5-15R, receptacles
  • UPS 1,500 VA / 1000 W Tower - (single phase)
    • 53962JX 1200 VA, 100 V AC, 60 Hz, 12.6 A
  • Output through 8 NEMA 5-20R, receptacles
  • UPS 1,500 VA / 1000 W Tower - (single phase)
    • 53962KX 1,500 VA, 220-240 V AC, 50 Hz, 6.9 A
  • Output through 8 IEC 320 C13 receptacles
  • Audible noise at 1 meter - 55 dBa (100% load)
  • Online thermal dissipation - 1AX, 1JX, 1KX - 853 BTU/hr
    • 2AX, 2JX, 2KX - 1708 BTU/hr

Operating Environment

  • Temperature:
    • 0 to 40.0 degrees Celsius (32 to 104 degrees Fahrenheit) at 0 to 3,000 m (0 to 9,843 ft)
  • Relative humidity: 5% to 95%
  • Maximum altitude: 3,000 m ( 9,843 ft)

Product marketing and replacement part numbers (FRU)

Description Marketing part number Replacement part number
IBM 1000VA LCD Tower UPS (120 V)
53961AX 69Y6071
IBM 1000VA LCD Tower UPS (100 V) (Japan only) 53961JX 69Y6077
IBM 1000VA LCD Tower UPS (230 V) 53961KX 69Y6081
IBM 1500VA LCD Tower UPS (120 V) 53962AX 69Y6082
IBM 1500VA LCD Tower UPS (100 V) (Japan only) 53962JX 69Y6086
IBM 1500VA LCD Tower UPS (230 V) 53962KX 69Y6087

Hardware requirements

None.

Software requirements

The 1000VA or 1500VA LCD UPS will provide backup power to your server regardless of the operating system used. However, to enjoy the benefits and manageability features provided with the IBM UPS Management Software (which is needed to shutdown the server gracefully during a power outage by receiving and processing the shutdown commands from the UPS or NMC based on the operating state of the UPS) via SNMP or serial, one of the following operating systems must be used:

  • Microsoft Windows XP Professional Edition
  • Microsoft Windows XP Professional x64 Edition
  • Microsoft Windows Server 2003/2003 R2, Enterprise Edition
  • Microsoft Windows Server 2003/2003 R2, Enterprise x64 Edition
  • Microsoft Windows Server 2003/2003 R2, Standard Edition
  • Microsoft Windows Server 2003/2003 R2, Standard x64 Edition
  • Microsoft Windows Vista Business x86
  • Microsoft Windows Vista Business x64
  • Microsoft Windows Vista Ultimate x86
  • Microsoft Windows Vista Ultimate x64
  • Microsoft Windows 7 Professional x86
  • Microsoft Windows 7 Professional x64
  • Microsoft Windows 7 Ultimate x86
  • Microsoft Windows 7 Ultimate x64
  • Microsoft Windows Server 2008, Enterprise x86 Edition
  • Microsoft Windows Server 2008, Enterprise x64 Edition
  • Microsoft Windows Server 2008, Standard x86 Edition
  • Microsoft Windows Server 2008, Standard x64 Edition
  • Microsoft Windows Server 2008, Standard Edition R2 x64 Edition
  • Red Hat Enterprise Linux 5 Server Edition
  • Red Hat Enterprise Linux 5 Server x64 Edition
  • Red Hat Enterprise Linux 4 AS for Intel x86
  • Red Hat Enterprise Linux 4 AS for 64 bit
  • Red Hat Enterprise Linux 4 ES for x86
  • Red Hat Enterprise Linux 4 ES for 64 bit
  • Red Hat Enterprise Linux 4 AS for iSeries and pSeries

Also, to enjoy the benefits and manageability features provided with the IBM UPS Management SW via USB, one of the following operating systems must be used:

  • Microsoft Windows XP Professional Edition
  • Microsoft Windows XP Professional x64 Edition
  • Microsoft Windows Server 2003/2003 R2, Enterprise Edition
  • Microsoft Windows Server 2003/2003 R2, Enterprise x64 Edition
  • Microsoft Windows Server 2003/2003 R2, Standard Edition
  • Microsoft Windows Server 2003/2003 R2, Standard x64 Edition
  • Microsoft Windows Vista Business x86
  • Microsoft Windows Vista Business x64
  • Microsoft Windows Vista Ultimate x86
  • Microsoft Windows Vista Ultimate x64
  • Microsoft Windows 7 Professional x86
  • Microsoft Windows 7 Professional x64
  • Microsoft Windows 7 Ultimate x86
  • Microsoft Windows 7 Ultimate x64
  • Microsoft Windows Server 2008, Enterprise x86 Edition
  • Microsoft Windows Server 2008, Enterprise x64 Edition
  • Microsoft Windows Server 2008, Standard x86 Edition
  • Microsoft Windows Server 2008, Standard x64 Edition
  • Microsoft Windows Server 2008, Standard Edition R2 x64 Edition

Compatibility

The IBM UPS 1000VA and 1500VA are compatible with all System x servers, as well as other supporting devices that require AC power.

Limitations

None.

Applicable countries and regions

 


Document id:  MIGR-5085810
Last modified:  2011-08-26
Copyright © 2014 IBM Corporation