Source
RETAIN tip: H205887
Symptom
When using UpdateXpress Service Pack Installer (UXSPI) to update the firmware of the Virtual Fabric 10 Gigabit (Gb) Switch Module for IBM BladeCenter, if the current active image is image2, then image1 is expected to be updated. However, in such case, it is still image2 that will be updated and after update, the active image will turn to image1.
Affected configurations
The system is configured with at least one of the following:
- UpdateXpress Service Pack Installer, version 5.00
This tip is not system specific.
This tip is not option specific.
Note: This does not imply that the network operating system will work under all combinations of hardware and software.
Please see the compatibility page for more information: http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/
Solution
This behavior will be corrected in a future release of UXSPI 12B.
The target date for this release is scheduled for second quarter 2012.
The file is or will be available by selecting the appropriate Product Group, type of System, Product name, Product machine type, and Operating system on IBM Support's Fix Central web page, at the following URL:
Workaround
After update, telnet or SSH to the switch and change the active image to image2 manually using the following command:
Additional information
The logic used by UXSPI to determine the active image for the switch is not correct.