CMM does not display hard drive presence information for Power Compute Node - IBM Flex System



Source

RETAIN tip: H207754

Symptom

The Chassis Management Module (CMM) does not display hard drive present in a Power Compute Node in the hardware inventory:

  • Chassis Management, Hardware Topology, Power compute node

Affected configurations

The system may be any of the following IBM servers:

  • Flex System p24L Compute Node, type 1457, any model
  • Flex System p260 Compute Node, type 7895, any model
  • Flex System p460 Compute Node, type 7895, any model

The system is configured with one or more of the following IBM Options:

  • Flex System Chassis Management Module, Option part number 68Y7029, any Replacement part number (CRU)

This tip is not software specific.

The system has the symptom described above.

The following system firmware level(s) are affected:

  • AF763_048_043 and previous

Solution

The fix is available in the AF773_033 release of Power Systems firmware.

The file will be available by selecting the appropriate Product Group, type of System, Product name, Product machine type, and Operating system on IBM Support's Fix Central web page, at the following URL:

Additional information

This issue occurs because the HDD presence information is not sent to the CMM by the power compute node firmware.

Applicable countries and regions

 


Document id:  MIGR-5092702
Last modified:  2013-10-25
Copyright © 2014 IBM Corporation